Laser Doppler Vibrometer
The laser doppler vibrometer can measure up to 16 points of transient or steady-state of vibration and has a multi-beam array generated by AOM. Its features include a field-programmable gate array processor for digital demodulation and novel laser aiming technology. The laser doppler vibrometer is commonly used in the following applications in the industry, aeronautics and space, automotive, hard disk drive diagnostics, micro and nanostructure analysis, civil structure analysis, medical and health care, as well as manufacturing QC.
| Specifications | Standard | Custom Design |
| Measurement point | 1 | – |
| Laser | He-Ne Laser (wavelength at 632.8nm, Class II, Eye-safe) | |
| Standoff distance | 0.2 – 5m (adjustable focal length, up to 30m with retro-reflective surfaces) | |
| Spot size of laser | 20µm – 500µm | |
| Output | Acceleration, velocity or displacement (selected from software) | |
| Frequency measurement range | 0.1hz – 250khz (Analog); Up to 5MHz (digital) | |
| Velocity measurement range | Adjustable based on resolution, from 10mm/s to 2m/s | |
| Resolution | Velocity: 0.02µm/s √Hz Displacement: 1pm | |
| Demodulation system | FPGA digital decoding system (real time output) | |
| Interface control | Software control | |
| Data output | Digital output (USB Type C) Analog output (SMA Interface) | |
| Mounting hole on system | M4, M6 1/4″ – 20 | Custom design |
| Software | Windows-based interface for display analyze and saving measurement data | Optional laptop with SSD |
| Power supply | USB Type C Interface can be charged by powerbank | – |
| Size of system (mm) | 300 (L) x 62 (W) x 120 (H) | |
| Trigger Interface | TTL Signal, SMA Interface | |
| Warranty | 1 year | Optional 2 years |