Objective Lentes

Microscopia apochromatica obiectiva lentes sunt infinitae systemata optica praesto in pluribus magnificationibus operantibus in regione spectrali a 355 ad 1064nm. Est specimen visionis co-axialis vigilantiae reali temporis sicut processus laseris, micro-imaginationis, DIC imaginationis, et fluorescentiae inspectionis in bio-imaginatio. Solebat etiam laser ad tactum tabulæ reparandum et cellam solarem.

Tubus Lens uti destinatur una cum lens obiectiva ad applicationes imaginandas. Lentem secundariam agit, praebens lucem transire per corpus tubi sicut radios parallelos a lens objecto. Hi radii paralleli a lente tubi feruntur ad imaginem mediam cum minima aberratione.

  • Microscopium obiectivum Lentes

Part No.NAWD (mm)FL (mm)Resolution (µm)± DOF (μm)Domi adsum (m)FOV φ24 mmFOV 1" CCD (mm).Pondus (g)
M-PlanAPO-1X0.02513.0200.0011.00440.00400-70024.009.60 x 12.80240
M-PlanAPO-2X0.05534.0100.005.0091.00400-70012.004.80 x 6.40206
M-PlanAPO-3.5X0.10041.057.142.8028.00400-7006.902.70 x 3.60218
M-PlanAPO-5X0.14035.040.002.0014.00400-7004.801.92 x 2.56212
M-PlanAPO-7.5X0.21034.026.671.306.20400-7003.601.28 x 1.70247
M-PlanAPO-10X0.28034.020.001.003.50400-7002.400.96 x 1.28217
M-PlanAPO-15X0.35022.013.330.802.20400-7001.800.64 x 0.85240
M-PlanAPO-20X0.42020.010.000.701.60400-7001.200.48 x 0.64271
M-PlanAPO-50X0.55013.04.000.500.90400-7000.480.19 x 0.26298
M-PlanAPO-HR-5X0.21025.040.001.306.20400-7004.801.92 x 2.56251
M-PlanAPO-HR-10X0.42015.020.000.701.60400-7002.400.96 x 1.28382
M-PlanAPO-HR-20X0.6009.510.000.500.76400-7001.200.48 x 0.64563
M-PlanAPO-HR-100X0.9001.42.000.300.34400-7000.240.10 x 0.13362
M-PlanAPO-SL-20X0.29030.010.000.903.30400-7001.200.48 x 0.64236
M-PlanAPO-SL-50X0.42020.04.000.701.60400-7000.480.19 x 0.26286
M-PlanAPO-SL-100X0.55013.02.000.500.90400-7000.240.10 x 0.13302
M-PlanAPO-NIR-20X0.42020.010.000.651.56532 / 1030 1064,1.200.48 x 0.64377
M-PlanAPO-NIR-50X0.55013.04.000.500.91532 / 1030 1064,0.480.19 x 0.26394
M-PlanAPO-HRNIR-20X0.6009.510.000.460.76532 / 1030 1064,1.200.48 x 0.64563
i-PlanAPO-HRNIR-50X0.67010.04.000.410.61532 / 1030 1064,0.480.19 x 0.26470
M-PlanAPO-HRNIR-50X0.7504.04.000.370.49532 / 1030 1064,0.480.19 x 0.26582
LCD-PlanAPO-NIR-20X(t0)0.40020.010.000.701.70532 / 1030 1064,1.200.48 x 0.64260
LCD-PlanAPO-NIR-20X(t0.7)0.40020.010.000.701.70532 / 1030 1064,1.200.48 x 0.64259
LCD-PlanAPO-NIR-20X(t1.1)0.40020.010.000.701.70532 / 1030 1064,1.200.48 x 0.64258
LCD-PlanAPO-NIR-50X(t0)0.45015.04.000.601.40532 / 1030 1064,0.480.19 x 0.26300
LCD-PlanAPO-NIR50X(t0.7)0.45015.04.000.601.40532 / 1030 1064,0.480.19 x 0.26299
LCD-PlanAPO-NIR50X(t1.1)0.45015.04.000.601.40532 / 1030 1064,0.480.19 x 0.26298
M-PlanAPO-NUV-20X0.42017.010.000.651.56355, 532 & 365, 4051.200.48 x 0.64268
M-PlanAPO-HRNUV-50X0.65010.04.000.420.65355, 532 & 365, 4050.480.19 x 0.26405
LCD-PlanAPO-NUV-20X(t0)0.40020.010.000.701.70355, 5321.200.48 x 0.64262
LCD-PlanAPO-NUV-20X(t0.7)0.40020.010.000.701.70355, 5321.200.48 x 0.64261
LCD-PlanAPO-NUV-20X(t1.1)0.40020.010.000.701.70355, 5321.200.48 x 0.64260
LCD-PlanAPO-NUV-50X(t0)0.45015.04.000.601.40355, 5320.480.19 x 0.26295
LCD-PlanAPO-NUV-50X(t0.7)0.45015.04.000.601.40355, 5320.480.19 x 0.26294
LCD-PlanAPO-NUV-50X(t1.1)0.45015.04.000.601.40355, 5320.480.19 x 0.26293

Nota: 't' in parte numeri significat crassitudinem vitrei operculi

  • Eyepiece obiectiva lentium

Part No.NAWD (mm)FL (mm)Resolution (µm)± DOF (μm)Ager NumberFOV (mm)Pondus (g)Thread
PlanFluor-EPI-5X0.1520401.8012.00255.0057W4/5" x 1/36"
PlanFluor-EPI-10X0.3011200.903.10252.5065W4/5" x 1/36"
PlanFluor-EPI-20X0.453100.601.40251.2577W4/5" x 1/36"
PlanFluor-EPI-50X0.80140.340.43250.5089W4/5" x 1/36"
PlanFluor-EPI-100X0.90120.310.34250.2590W4/5" x 1/36"
PlanFluor-EPI-BD-5X0.1520401.8012.00255.0078M26 x II
PlanFluor-EPI-BD-10X0.3011200.903.10252.5095M26 x II
PlanFluor-EPI-BD-20X0.453100.601.40251.25111M26 x II
PlanFluor-EPI-BD-50X0.80140.340.43250.50123M26 x II
PlanFluor-EPI-BD-100X0.90120.310.34250.25122M26 x II
L-PlanFluor-EPI-20X0.4012100.701.70251.2565W4/5" x 1/36"
L-PlanFluor-EPI-50X0.5010.440.551.10250.5068W4/5" x 1/36"
L-PlanFluor-EPI-100X0.803.120.340.43250.2588W4/5" x 1/36"

  • Tubus Lens

Part

Efl (mm).

WD (mm)

Longitudo habitationi (mm)

TL-200-70

200

60.36

70

  • objective Lente distarent,

Objective Lens Diagram

  • Tubus Lens

Objective Lens Tube Lens Diagram

Product Page Contact Form

Monemus uti inscriptionem tuam organizationem cum suo ditione (si quis).

FAQ

Quid est lens obiectiva in microscopio?

Lens obiectiva microscopii responsabilis est colligere et tendere lucem e specimine observato ad imaginem producendam. Prope fundum corporis microscopii typice sita est et in serie lentium quae simul ad imaginem speciminis amplificandam concurrunt.

Lens objectiva talis dicitur quia est lens proxima objecto observato. magnificatio microscopii potentia determinatur per magnificationem lens objecti et magnificationem lens eyepiece sive tubi.

Plures lentium obiectivarum in microscopio de more sunt, unaquaeque cum alia potentia magnificationis. Usor inter lentium commutare potest ut diversas partes speciminis in diversis gradibus magnificationis observet.

Show iecit, 23 - 26 Jan 2024 | Booth: 40013
Photonics Occidentalis, 30 Jan - 1 Feb 2024 | Booth: 2261
Commercial Sensu SPIE defensionis +, 2 - 4 May | Booth: 1320
Laser World of Photos, 27-30 June | Hall: B1 Booth: 422
Laser Mundus Photonics Indiae, 13-15 Septembris | Aula: 3 Booth: LF15
DSEI extensio, 12-15 Septembris | Booth: Vestibulum Pod 7