Athermal Lenses
The need to maintain focus over a wide range of environmental temperatures is essential to system performance, stability, and high quality. Athermalized lenses kept their performance from changing by means of optical passivity, mechanical activity, and mechanical passivity in a large temperature range. Its configuration will auto-adjust itself when placed at different temperatures.
Customization is available for this product. Let us know your specifications in the RFQ form.
| Part Number | Wavelength (µm) | Focal Length (mm) | Focus Type | F# | BWD (mm) | Mount | Detector |
|---|---|---|---|---|---|---|---|
| Infra-LW211.0-21A *NEW | 8.0 - 14.0 | 21.0 | Fixed Focus | 1.0 | 9.50 | M34x0.75 | 1280 x 1024, 12µm |
| Infra-LW601.0-21AV3 *NEW | 8.0 - 14.0 | 60.0 | Fixed Focus | 1.0 | 9.50 | M34x0.5 | 1280 x 1024, 12µm |
| Infra-LW351.2-21A | 8.0 - 12.0 | 35.0 | Fixed Focus | 1.2 | 9.99 | M34x0.5 | 1024 x 768, 17µm |
| Infra-LW151.0-21A | 8.0 - 14.0 | 15.0 | Fixed Focus | 1.0 | 10.00 | M45x0.75 | 1280 x 1024, 12µm |
| Infra-LW131.0-21A | 8.0 - 14.0 | 13.0 | Fixed Focus | 1.0 | 11.91 | M45x0.75 | 1280 x 1024, 12µm |
| Infra-LW351.0-21A | 8.0 - 12.0 | 35.0 | Fixed Focus | 1.0 | 9.00 | M45x1 | 1024 x 768, 17µm |
| Infra-LW601.0-21A | 8.0 - 14.0 | 60.0 | Fixed Focus | 1.0 | 9.50 | M34x0.5 | 1280 x 1024, 12µm |
| Infra-LW1001.2-12A | 8.0 - 12.0 | 100.0 | Fixed Focus | 1.2 | 9.70 | M34x0.5 | 640 x 480, 17µm |
| Infra-LW1000.9-21A | 8.0 - 14.0 | 100.0 | Fixed Focus | 0.9 | 9.40 | M54x0.75 | 1280 x 1024, 12µm |
| Infra-LW751.0-21A | 8.0 - 12.0 | 75.0 | Fixed Focus | 1.0 | 9.03 | M45x1 | 1280 x 1024, 12µm |
| Infra-LW6.91.0-17A | 8.0 - 14.0 | 6.9 | Fixed Focus | 1.0 | 3.24 | Flange | 640 x 480, 17µm |
| Infra-LW7.51.0-17A | 8.0 - 14.0 | 7.5 | Fixed Focus | 1.0 | 9.00 | M25x0.5 | 640 x 480, 17µm |
| Infra-LW8.51.2-17A | 8.0 - 14.0 | 8.5 | Manual Focus | 1.2 | 10.47 | M34x0.5 | 640 x 480, 17µm |
| Infra-LW91.0-17A | 8.0 - 14.0 | 9.0 | Fixed Focus | 1.0 | 9.11 | M34 x 0.5 | 640 x 480, 17µm |
| Infra-LW111.0-17A | 8.0 - 14.0 | 11.0 | Manual Focus | 1.0 | 11.00 | M34x0.5 | 640 x 480, 17µm |
| Infra-LW131.0-17A | 8.0 - 14.0 | 13.0 | Fixed Focus | 1.0 | 8.77 | M25x0.5 | 640 x 480, 17µm |
| Infra-LW151.0-17A | 8.0 - 14.0 | 15.0 | Manual Focus | 1.0 | 8.00 | M34x0.75 | 640 x 480, 17µm |
| Infra-LW150.85-17A | 8.0 - 14.0 | 15.0 | Fixed Focus | 0.9 | 8.50 | M34 x 1 | 640 x 480, 17µm |
| Infra-LW151.0-17AV2 | 8.0 - 12.0 | 15.0 | Fixed Focus | 1.0 | 8.77 | M25 x 0.5 | 640 x 480, 17µm |
| Infra-LW191.2-17A | 8.0 - 14.0 | 19.0 | Manual Focus | 1.2 | 10.47 | M34x0.5 | 640 x 480, 17µm |
| Infra-LW191.0-17A | 8.0 - 14.0 | 19.0 | Fixed Focus | 1.0 | 8.00 | M29 x 0.75 | 640 x 480, 17µm |
| Infra-LW251.2-17A | 8.0 - 14.0 | 25.0 | Manual Focus | 1.2 | 10.47 | M34x0.5 | 640 x 480, 17µm |
| Infra-LW251.0-17A | 8.0 - 14.0 | 25.0 | Fixed Focus | 1.0 | 9.00 | M34 x 0.75 | 640 x 480, 17µm |
| Infra-LW301.0-17A | 8.0 - 14.0 | 30.0 | Fixed Focus | 1.0 | 9.35 | M34 x 0.5 | 640 x 480, 17µm |
| Infra-LW351.2-17A | 8.0 - 14.0 | 35.0 | Manual Focus | 1.2 | 10.47 | M34x0.5 | 640 x 480, 17µm |
| Infra-LW351.0-17A | 8.0 - 14.0 | 35.0 | Fixed Focus | 1.0 | 4.50 | M25 x 0.5 | 640 x 480, 17µm |
| Infra-LW401.0-17A | 8.0 - 14.0 | 40.0 | Fixed Focus | 1.0 | 6.50 | M34 x 0.75 | 640 x 480, 17µm |
| Infra-LW501.0-17A | 8.0 - 14.0 | 50.0 | Fixed Focus | 1.0 | 7.70 | M34x0.75 | 640 x 480, 17µm |
| Infra-LW601.0-17A | 8.0 - 14.0 | 60.0 | Fixed Focus | 1.0 | 8.00 | M34 x 0.75 | 640 x 480, 17µm |
| Infra-LW601.25-17A | 8.0 - 14.0 | 60.0 | Manual Focus | 1.3 | 10.47 | M34x0.5 | 640 x 480, 17µm |
| Infra-LW701.0-17A | 8.0 - 14.0 | 70.0 | Fixed Focus | 1.0 | 11.00 | M34 x 0.75 | 640 x 480, 17µm |
| Infra-LW751.0-17A | 8.0 - 14.0 | 75.0 | Fixed Focus | 1.0 | 5.70 | M34 x 0.75 | 640 x 480, 17µm |
| Infra-LW751.3-17A | 8.0 - 14.0 | 75.0 | Fixed Focus | 1.3 | 11.00 | M34 x 0.75 | 640 x 480, 17µm |
| Infra-LW1001.0-17A | 8.0 - 14.0 | 100.0 | Fixed Focus | 1.0 | 13.50 | Flange | 640 x 480, 17µm |
| Infra-LW1001.2-17A | 8.0 - 14.0 | 100.0 | Fixed Focus | 1.2 | 9.50 | M38.5 x 0.75 | 640 x 512, 17µm |
| Infra-LW1001.5-17A | 8.0 - 14.0 | 100.0 | Manual Focus | 1.5 | 10.47 | M34x0.5 | 640 x 480, 17µm |
Athermal Lenses Information
Focusing Type: Manual or Fixed
Operating Temperature: ±40℃ ~ +60℃
Storage Temperature: ±20℃ ~ +80℃
Athermal Lenses Application
Athermal Lenses Knowledge Hub
Infrared Thermal Imaging Technology in Non-Destructive Inspection of Ship Structures
The infrared thermal imaging system plays a key role in the non-destructive structural investigation in the shipbuilding industry.
Read moreWhat are Infrared Optics? An Introduction to Infrared Optics
Infrared optics are used to collect, focus or collimate light in the near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR) or long-wave infrared (LWIR) spectra....
Read more