T-SPECTRALYZER F

T-SPECTRALYZER F

   The Fiber-Coupled THz-Spectrometer

HUBNER_T-SPECTRALYZER_F

T-SPECTRALYZER F is a Plug & Play THz-Spectrometer that facilitates non-destructive and contact-free analysis of your samples.

Individual measurement modules and an intuitive user interface support the recording, processing and exporting of your measurement results. T-SPECTRALYZER F is a high-performance THz-Spectrometer offering the frequency range 0.1 – 2.5 THz and a dynamic range of up to 54 dB*.

Short measurement times of 0.05s allow the monitoring of processes or spatial mapping of your samples. The operation is user-friendly – no time consuming training is required. The standardized hardware and software interfaces help you to integrate the spectrometer into your existing network and process flow. No safety precautions are necessary as terahertz waves are completely safe.

Module Dynamic Range
   
Spetral Signal & Noise Information (Typical) Noise Dependent Signal & Noise Information (Typical)

Possible Applications:

The T-SPECTRALYZER F opens up new dimensions in many
fields of measurement applications, for example:

Determining the layer thicknesses of multi-layer systems

Identification of substances even through plastic pipes and
  tubes or other packaging

Analysis of chemicals in powder and tablet form

Analysis of liquids and gases

Characterization of doped semiconductor materials

Investigation of moisture distributions

Determination of the filling level of polymers

Distinguishing various isomers

Distinguishing crystalline and amorphous structures


System specifications*

Frequency range: 0.1 THz up to 2.5 THz
(33 cm -1 up to 133 cm -1 )
Dynamic range: > 54 dB at 0.5 THz (16.7 cm -1 )

 

Frequency resolution:

Standard: 10 GHz (Meas. range 100 ps)
Maximum: 5 GHz (Meas. range 200 ps)

Measurement time:
Standard: 5 s (100 ps at 20 ps/s)
Minimum: 0.05 s (100 ps at 2,000 ps/s)

Sample scan range/beam diameter:
Standard: 200 x 200 mm 2 
(~ 0.2 mm accuracy)
Beam diameter: ~ 1.5 mm
(frequency-dependent)
Dimensions and weight:
19" rack
W x H x D 43 x 27 x 46 cm 3
Weight 30 kg
Terahertz transmitter/ detector module (each)
W x H x D 5 x 5 x 10 cm 3
Weight 0,5 kg

Surroundings and electrical supply
Operation temperature 16 - 32°C (60 - 90°F)
Operating voltage 115 - 230 VAC
Frequency 50 - 60 Hz
Power consumption < 200 Watt
 

 

 

 

 

 

 

 

 

 

 


*All shown data measured with fiber-coupled transmitter and detector modules, 5 m fiber each, with two collimating and two focusing TPX lenses (four lenses overall), without any sample at 5 s of measurement time, 100 ps of measurement range, 10 GHz of frequency resolution, a temperature of 22 °C, relative humidity of 27 %.

COPYRIGHTS © 2014 WAVELENGTH OPTO-ELECTRONIC (S) PTE LTD